Why is the spectrophotometer set at 0.000 absorbance




















If the absorbance increases to a value greater than 3. Dilute the solution and try again. It is possible to release the control from the pc, but not activate it. Measure at one wavelength Spectrum, wavelength scan Baseline, wavelength scan Zero value absorbance , transmittance Release control. You can also use the terminal program in Datalyse with the spectrophotometer.

Before Cecil 20xx is capable of scanning, you have to measure a baseline. Place a cuvette containing only water in the holder or leave it empty and make a base scan. This takes from a few minutes to 15 minutes depending on the selected scan speed. Putting that all together, a "spectrophotometer" is a device capable of making quantitative measurements of light intensity at selected wavelengths.

Its components include a light source or sources, devices sometimes incorporating filters for generating beams of light of specific wavelengths from that source, special holding devices for tubes or "cuvettes" containing samples through which light beams are passed, and detectors that can measure the intensity of light that has passed through a sample.

Some spectrophotometers used in bioresearch are designed for analysis of both ultraviolet UV and visible VIS regions of the spectrum, while others are VIS range only.

The former are more useful because many biomolecules of interest, such as nucleic acids and proteins, absorb wavelengths in the UV range. They are correspondingly more expensive instruments, however. However, if you use a spectrophotometer in a research laboratory, it is likely that it will be UV-VIS. Identification of compounds : When matter interacts with energy, energy is frequently absorbed. Different types of chemical compounds have distinctive atomic and molecular structure, and will absorb energy at characteristic energy levels and wavelengths.

In some cases, absorbed light energy is re-emitted as light of lower energy and longer wavelength. This phenomenon is known as "fluorescence". An unknown substance can often be identified by comparing the amount of light of different wavelengths that it absorbs, i. Such an analysis is performed using a spectrophotometer to measure the amount of light absorbed over a range of wavelengths of incident light.

A solution looks colored to the human eye because molecules are absorbing wavelengths corresponding to the other colors. It appears as a particular color because it is NOT absorbing the wavelengths of that color; rather, they are transmitted to your eye. For example, a compound appearing blue in solution is transmitting a range of nm wavelengths to the eye, and is typically absorbing at yellow.

A compound appearing red is typically transmitting in a range of nm, and absorbing in the nm range bluish-green. Concentration determination : The concentration of an unknown sample can also be determined using a spectrophotometer. When a light beam is passed through a sample, part of it is absorbed, and part is transmitted through the sample.

To quantify this effect, the transmittance T is defined as the intensity of the transmitted light I t divided by the original or incident intensity of the light beam I o. The absorbance A is defined as the log 10 of the reciprocal of the transmittance, i.

This is a measure of how much light is absorbed by the sample, rather than transmitted through it. Knowing one A or T it is easy to calculate the other. There is a relationship between concentration and absorbance; the higher the concentration of a substance in a solution, the greater the amount of light it will absorb, assuming that the wavelength is an absorbable one for the substance.

You will determine the relationship between concentration and absorbance in Exercise 5, below. Since a spectrophotometer measures absorbance or transmittance, from which absorbance can be calculated , the spectrophotometer can be used to determine an unknown concentration of a substance by comparison with a "Standard Curve", i.

Go to the spectrophotometer and examine it for the following components, reviewing their functions:. Absorbance modes measurements. Transmittance or zero absorbance. RSC computer or Printer interface. Review the following information on operation of the spectrophotometer before proceeding to the next exercise. Do not actually carry out any of these steps at this time. The spectrophotometer should already be plugged in. If not, plug one end the power cord into a wall outlet, the other end into rear of spectrophotometer.

Turn on the spectrophotometer and allow it to warm up for at least twenty minutes to stabilize the electronic components. Prepare a "blank" tube. The blank is used as a control. Therefore it should contain exactly the same medium or media in the same amounts as used to prepare your samples , except that it contains none of the compound or substance under study.

For example, if your sample is prepared in buffer, and you need 1ml of this sample to measure absorbance then the blank small test tube should be filled with the 1ml same buffer. If your sample is in deionized water, the blank should also be filled with deionized water. Open the sample compartment and place the blank into it. Turn the wavelength dial to the desired wavelength. Set the filter selector located in the sample compartment to the appropriate position.

Follow directions on inner panel of the sample compartment. For example, if you have set the wavelength to nm, set the filter selector to position 3. Close the sample compartment. Remember there are different filter settings for different wavelength ranges. Don't forget to switch the setting when appropriate!

The display should show Carefully open the sample compartment and remove the test tube, placing it in test tube rack nearby. Fill a clean small test tube with the solution to be measured.

Place the small test tube into the compartment and close it. The display shows the transmittance or absorbance immediately. Record the value s and remove the test tubes. Measuring Absorbance with Spectrophotometer Turn on the spectrophotometer. Let it warm up for 15 minutes. Select wavelength scan.

The light needs to pass through clear area on cuvette. Press "Zero" Remove the blank. Determine optimum wavelength absorbance and set up data collection mode. Record the wavelength and absorbance in Table 6. Decide which dyes were used to make each color.

Enter the Wavelength of that dye in the last column of table 6. Explain your reasoning for each choice in your lab notebook. Results Table 2. Instructions for Cleaning Cuvettes Discard solutions to sink Rinse with tap water once Rinse with DI water two times Place in tube rack, allow to air dry. Study Questions Name the parts of the spectrophotometer and identify their function. How did you determine which wavelength was absorbed at the highest level?

How is this process useful in determining the identity of a molecule? How do you clean a cuvette? Brilliant Blue FCF. Solid Green FCF. Indigo Carmine.

Allura Red AC. Sunset Yellow FCF.